نتایج جستجو برای: spiral ct

تعداد نتایج: 154953  

Journal: :journal of dental research, dental clinics, dental prospects 0
farzaneh kaviani assistant professor, department of oral and maxillofacial radiology, faculty of dentistry tabriz university of medical science, tabriz, iran reza javadrashid assistant professor, department of radiology, faculty of medicine, tabriz university of medical science, tabriz, iran zahra shahmoradi post graduate student, department of oral and maxillofacial radiology, faculty of medical, tabriz university of medical science, tabriz, iran masoud gholamian post graduate student, department of radiology, faculty of medicine, tabriz university of medical science, tabriz, iran

background and aims. the imaging techniques commonly used for foreign body detection include plain radiography, xeroradiography, computed tomography (ct) scans, magnetic resonance imaging (mri) and ultrasonography. the aim of the present study was to compare cone-beam computed tomography (cbct) with conventional ct scan in determination of the exact location of a foreign body in the maxillofaci...

Journal: :iranian journal of radiology 0
saeed naghibi department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran; department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran. tel: +98-9151158630, fax: +98-5137613248 sirous seifirad department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran mahboobeh adami dehkordi department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran sasan einolghozati department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran nafiseh ghaffarian eidgahi moghadam department of radiology, faculty of medicine, mashhad branch, islamic azad university, mashhad, iran amir akhavan rezayat department of radiology, mashhad university of medical sciences, mashhad, iran

conclusion spiral-ct scan is superior to conventional ct in the diagnosis of lesions in com before operation. it can be used for detailed evaluation of ossicular chain in such patients. objectives this study was performed to compare the findings of three-dimensional reconstructed spiral and conventional ct scan of ossicular chain study in patients with com. patients and methods fifty patients e...

Journal: :jundishapur journal of microbiology 0
seyed ali javad moosavi internal medicine department, tehran university of medical sciences, tehran, ir iran hanieh raji internal medicine department, jundishapur university of medical sciences and health services, ahvaz, ir iran; jundishapur university of medical sciences and health services, ahvaz, ir iran. tel: +98-6114163728 mahshid talebi-taher internal medicine department, tehran university of medical sciences, tehran, ir iran shadi ghourchian scientific research center, tehran university of medical sciences, tehran, ir iran

background since tuberculosis (tb) is a major public health problem that is a leading cause of mortality and morbidity among infectious diseases worldwide, early diagnosis and treatment are important to control an effective tuberculosis (tb) and also the increasing number of patients with atypical manifestations of active tb. it suggests more evaluation for active tb in fibrotic lesion in ct sc...

Journal: :iranian journal of radiation research 0
s.m. ghavami radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran a. mesbahi medical physics department, medical school, tabriz university of medical sciences, tabriz, iran i. pesianian radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran

background: x-ray computed tomography (ct) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. the objective of the current study was to analyze and investigate the average patient received dose from axial and spiral ct exams in a medical imaging center. material and methods: in this study, the patient imaging technique, w...

 علی عباسی, , حسن توکلی, , خدیجه بخت آور, , فرانک خدادادی, , هادی احمدی, ,

Background: Acute abdominal pain is a common complaint in an emergency setting. An immediate and precise diagnosis is necessary for reducing morbidity and mortality. Several studies have reported that CT scan increases diagnostic accuracy for patients with acute abdominal pain. This study was designed to evaluate the sensitivity, specificity and accuracy of spiral CT scan compared to that of ab...

A. Mesbahi, I. Pesianian, S.M. Ghavami,

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

Journal: :trauma monthly 0
ameya jagdish baxi department of radiology, university of texas health science center, san antonio, usa; department of radiology, university of texas health science center, san antonio, usa. tel: +1-2105675535 carlos restrepo department of radiology, university of texas health science center, san antonio, usa amy mumbower department of radiology, university of texas health science center, san antonio, usa michael mccarthy department of radiology, university of texas health science center, san antonio, usa katre rashmi department of radiology, university of texas health science center, san antonio, usa

trauma is the leading cause of death in united states in the younger population. cardiac trauma is common following blunt chest injuries and is associated with high morbidity and mortality. this study discusses various multidetector computed tomography (mdct) findings of cardiac trauma. cardiac injuries are broadly categorized into the most commonly occurring blunt cardiac injury and the less c...

MohammadReza Deevband Pardis Ghafarian Yazdan Salimi

Introduction: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. Materials and Methods: A special wedding cake phantom with circular in...

ژورنال: مجله دندانپزشکی 2011
اسکندرلو, امیر, رحیمی, عزیزاله, رستم پور, نیما, قاضی خانلو ثانی, کریم ,

Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT), conventional and spiral computed tomography (CT).Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TL...

Journal: :Thorax 1998
P A Grenier C Beigelman

PURPOSE To compare prospectively the accuracy of spiral computed tomography (CT) with that of ventilation-perfusion scintigraphy for diagnosing pulmonary embolism. MATERIALS AND METHODS Within 48 hours of presentation, 142 patients suspected of having pulmonary embolism underwent spiral CT, scintigraphy, and (when indicated) pulmonary angiography. Pulmonary angiography was attempted if interp...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید